Basic Specs
Basic Specs
Model
AVIA
Laser Wavelength
905 nm
Laser Safety
Class 1 (IEC60825-1:2014)(Eye Safety)
Detection Range (@ 100 klx)
190 m @ 10% reflectivity
230 m @ 20% reflectivity
320 m @ 80% reflectivity
230 m @ 20% reflectivity
320 m @ 80% reflectivity
Detection Range (@ 0 klx)
190 m @ 10% reflectivity
260 m @ 20% reflectivity
450 m @ 80% reflectivity
260 m @ 20% reflectivity
450 m @ 80% reflectivity
FOV
Non-repetitve scanning pattern:
70.4° (Horizontal) ×77.2° (Vertical)
Repetitve line scanning:
70.4° (Horizontal) ×4.5° (Vertical)
70.4° (Horizontal) ×77.2° (Vertical)
Repetitve line scanning:
70.4° (Horizontal) ×4.5° (Vertical)
Range Precision (1σ @ 20m)
2 cm¹
Angular Precision(1σ )
< 0.05º
Beam Divergence
0.28° (Vertical) × 0.03° (Horizontal)
Point Rate
240,000 points/s (first or strongest return)
480,000 points/s (dual return)
720,000 points/s (triple return)
480,000 points/s (dual return)
720,000 points/s (triple return)
Data Latency
≤ 2 ms
Data Port
100 Mbps Ethernet
Data synchronization:
IEEE 1588-2008 (PTPv2), PPS (Pulse Per Second), GPS (PPS+UTC)
False Alarm Rate (@ 100 klx) ²
< 0.0003%
IMU
Built-in model: BMI088
Operating Temperature
-4°F to 149°F (-20℃ to 65℃)
IP Rating ³
IP67
Power ⁴
Repetitive scanning pattern: 9 W (Startup: 16W)
Non-repetitive: 8 W (Startup: 16W)
Non-repetitive: 8 W (Startup: 16W)
Power Supply Voltage Range ⁵
10 ~ 15 V DC(with Converter 2.0: 9~30V DC )
Noise
40cm omnidirectional <45 dBA
Dimensions
91×61.2×64.8 mm
Weight
498 g (without cables)
Notes
1. Measured in an environment of 25℃ with a target (80% reflectivity) 20 meters away. The result may vary under different test conditions.
2. The false alarms ratio of the noise created by the stray light in a test environment of 0 to 100 klx at a temperature of 25℃.
3. The Livox Avia has an overall IP rating of IP67 (not including Livox Converter 2.0 and cables)
4. Starting power, especially at low temperature, might be significantly larger than the typical power. Please refer to user manuals for detailed information.
5. Make sure the output voltage of the power supply is within this range at all times.
2. The false alarms ratio of the noise created by the stray light in a test environment of 0 to 100 klx at a temperature of 25℃.
3. The Livox Avia has an overall IP rating of IP67 (not including Livox Converter 2.0 and cables)
4. Starting power, especially at low temperature, might be significantly larger than the typical power. Please refer to user manuals for detailed information.
5. Make sure the output voltage of the power supply is within this range at all times.